Korea Conformity Laboratories
06 / 2025ARCCON-352
EV battery testing - Mobile Climate Test Container (35 feet), with two test chambers.
-40…+130˚C
20…95%RH
Mobile Climate Test Container (35 feet).
ARCCON-352
Temperature range, -40ºC...+130ºC
Temperature change rate, 3ºC/min according to IEC 60068-3-5
Humidity range, 20%...95%RH
Fluctuation,
± 0,5ºC / ± 4,0%RH
The both chambers can be in any climate mode, independent from each other.